Subject:  ICOM I290 Modification



OBJECTIVE:

---------



The objective of the modification is to implement a delay before scanning

restarts when, in SCAN-STOP mode on BUSY frequency, the received signal

disappears.



The modification will then allow a frequency to be free for a while before

scanning resumes.

With this modification, it will be given a chance to a signal to come back

within a few seconds before the scanning restarts.

Now multiple QSOs or poor signals won't be truncated any more because of

a too much impatient scanning !



WHAT TO DO:

----------



Very simple. On the SENSOR UNIT, just solder a jumper between:

                - the unused contact of switch S3 (the one corresponding to

                  the TIMER OFF position of the circuit commanding the SEL

                  pin of IC1)

                - and the EMPTY signal of connector J3 (this is the extreme

                  pin nearest S2 on the SENSOR unit)



      ATTENTION, there are some errors on the electrical scheme that I possess

                  reference A-0488 :



                 * The S3 switch is represented in position TIMER OFF and not

                   ON as written. You have to reverse labels OFF and ON.



                 * The signals BUSY and EMPTY on connected are reversed.

                   EMPTY  (SQ1) is on the extreme left pin of S3 and  BUSY is

                   on 2nd pin of this connector S3.

                   In fact, the switch S2 is drawn in the BUSY position and

                   not EMPTY.



HOW IT WORKS :

-------------



The TIMER starts when pin SEL of IC1 goes to 0V.  When the TIMER is running,

the scanning is halted.

The scanning also stops when the BUSY signal is low level (0V) on pin SQL of

IC1.

Let us suppose that a signal is received. Then BUSY goes to 0V and scanning

halts.  At the same time  the EMPTY signal , which is the inverse of BUSY, goes

to 5V and the TIMER remains off.



If the received signal disappears BUSY goes high and EMPTY low, then the TIMER

is enabled and starts running. It also maintains the scanning in halt mode.



If, at the end of the TIMER delay, no signal has come back then the scanning

restarts.

If a signal comes back before the end of the TIMER delay then the BUSY signal

returns to 0V and maintains the scanning in halt mode. In the meantime the

TIMER will run until the end of its delay without any action on the process.



The TIMER delay is chosen with the R32 potentiometer on the SENSOR UNIT.

The minimum value is about 4 to 5 seconds which is perfect for this working

mode.



CONCLUSION:

----------

Small modification ....  great effect !

Gabriel F6DQM
SOURCE: The QRZ Windows Ham Radio CDROM



www.alwaysfree.nl - Web Reputation








Free Backlinks, Get 500 Free Backlinks Automatic Creation.

GET NOW 500 FREE BACKLINK AUTOMATIC




Do you need targeted visitors, get now 200 free visitors.

DO YOU NEED TARGETED VISITORS TO YOUR WEBSITE, GET NOW 200 FREE VISITORS




2 GB Storage That You Get At Free Web Hosting From www.hostinger.co.uk

FREE WEBSITE HOSTING IN UK WITH PHP AND MYSQL, WEBSITE BUILDER, NO ADS




Submit Here Your Website To The Web's Top 50 From Search Engines for Free

SUBMIT YOUR WEBSITE TO THE TOP 50 OF THE BEST SEARCH ENGINES FOR FREE




The World of Free Packet Radio Software Amsterdam
The World of Free Packet Radio Software Amsterdam The Netherlands

The World of Free Packet Radio Software Amsterdam The Netherlands - All Rights Reserved